SL8040 Salinometer for Ballast Water Treatment

Product Description:

Function
The salinometer measures and supervises the salinity (salt content) by conductivity measurement in sea water. The measured 
value is displayed as ‰, and, by comparing the measured value to a user defined alarm setpoint value, relay outputs are available 
to indicate if salinity is above or below the alarm setpoint value. 

Typical Use
In areas where fresh water generation or purification is taking place and level of salinity in the sea water must be monitored 
as well as in areas where a set level of salinity is requested in a process. Salinometers are used in: Freshwater Generators, Ballast Water Treatment Systems, Reversed Osmosis Fresh Water Systems (RO) and other systems where salinity has to be supervised. 

Mains Supply
85 - 265 V AC,  50/60 Hz,  10 VA typ. - 15 VA max. 
Mains supply must be protected against overcurrent by an external 250 mA slow-blow fuse.

Measuring Salinity Range 
0 - 40‰, displayed as “000” to “39,9” and “HI” if value exceeds 40‰. 

Alarm Function
User defined alarm setpoint value (0 - 39,9‰) is set using “+” and “-“ buttons. When measured value exceeds alarm setpoint, change-over relay contacts A and B are activated. Alarm relay B may be enabled/disabled from the front by pressing a button. 